Simple testing way of GTR module

Small story: Jack purchased darlington from supplier A,when he got it, fixed on the machine at once. But it still did't work. So Jack contacted with A for the problem. A said there's problem of the machine not module.So what's the problem?
Why we don't test darlington before fixing?
Don't know how to test? Here's the way.

Device and Equipment:
1) GTR Module( Darlington Module).
2) Pointer multimeter with 10K ohms file. Figure: We choose MF47 multimeter.

First multimeter zero modulation: Touch red table of multimeter pen with the black pen. Ensure Multimeter pointer pointing to the zero through whirling the nearby fine-tuning knob.

1. Simple testing method of single tube GTR module

For example, we test: QM300HA-2H and QM20HA-HB

Schematic of single tube GTR module: C, collector; B, trigger; E, emitter.

1). Turn the multimeter at 10K Ohm file, touch the black pen contact with E, the red pen with C. The multimeter show on state, which we call it as "Forward Conduction".Oppositely, touch the black pen contact with C, the red pen with E. The multimeter show the off state, which we call is as "Reverse non- conduction."

1)Turn the multimeter at 10K Ohm file, touch the black pen contact with E, the red pen with B. Or oppositely, touch the black pen contact with B, the red pen with E, the mulsimeter show the resistance is 30-90 ohm.

                                   1.1                                                                     1.2

                 1.3

2. Simple testing method of 2U GTR module

For example, we test: QM30DY-H.

Schematic of 2U GTR module: C, collector; B, trigger; E, emitter. C2E1 and  E2 is collector and emitter of 1 unit, C1 and C2E1 is collector and emitter of another unit.

1). Turn the multimeter at 10K Ohm file, touch the black pen contact with E2, the red pen with C2E1. The multimeter show on state, which we call it as "Forward Conduction".Oppositely, touch the black pen contact with C2E1, the red pen with E2. The multimeter show the off state, which we call is as "Reverse non- conduction."

2). Turn the multimeter at 10K Ohm file, touch the black pen contact with E2, the red pen with B2. Or oppositely, touch the black pen contact with B2, the red pen with E2, the mulsimeter show the resistance is 30-90 ohm. This shows that the unit circuit between C2E1 and E2 is in good condition.

3). Turn the multimeter at 10K Ohm file, touch the black pen contact with C1, the red pen with C2E1, the multimeter off state. Oppositely, touch the black pen contact with C1, the red pen with C2E1, the mulsimeter on state.Touch the black pen contact with E1, the red pen with B1, Or oppositely, the black pen with B1, the red pen with E1, the mulsimeter show the resistance is 30-90 ohm. This shows that the unit circuit between C2E1 and C1 is in good condition.

                                    2.1                                                                        2.2

3. Simple testing method of six tube GTR module

For example, we test: QM75TX-H.

Schematic of 6 tube GTR module: C, collector; B, trigger; E, emitter. P with U, V and W are three units respectively, N with U, V and W are the other three units respectiverly. Six units totally.

1). Testing method of three units between N with U, V and W.

Turn the multimeter at 10K Ohm file, touch the black pen contact with N, the red pen with U, V and W respectively. The multimeter show on state; Touch the black pen contact with BUN, BVN and BWN, the red pen correspond to U, V, and W. The mulsimeter show the resistance is 30-90 ohm.This shows that the 3 unit circuit between N and U, V, W are in good condition.

                                   3.1                                                                     3.2

2). Testing method of the other three units between P with U, V and W.

Turn the multimeter at 10K Ohm file, touch the black pen contact with P, the red pen with U, V and W respectively. The multimeter show off state; Oppositely, touch the red pen contact with P, the black pen with U, V and W respectively. The multimeter show on state. Touch the black pen contact with BUP, BVP and BWP, the red pen correspond to U, V, and W. The mulsimeter show the resistance is 30-90 ohm.This shows that the 3 unit circuit between P and U, V, W are in good condition.

                                    3.3                                                               3.4